Built environment inputs priority

The housing and building stock, insulation, behaviour and weather inputs all influence the heat demand. Because ETEngine applies inputs one after another (see Priority for the general mechanism), the order in which these inputs run matters. Running them in the wrong order silently produces incorrect results rather than an error.

This page documents the priority order used for these inputs, and the reasoning behind it, so that future additions or changes respect the same ordering. These priorities order is also documented as a comment at the top of each of the relevant .ad files in etsource, so it stays visible to anyone editing them directly.

Priorities

Recall that a higher priority number runs earlier. The building/housing inputs use the following order (highest to lowest):

4. Shares of new residences

  • households_share_of_<housing_type>

These inputs don't update anything themselves; they only need to have a value available (as a share group, summing to 100%) before the total number of new residences is distributed across housing types.

3. Building and housing stock

  • households_number_of_residences_new
  • households_demolished_<construction_period>
  • buildings_number_of_buildings_new
  • buildings_number_of_buildings_demolished

These read the shares set using priority 4 (via INPUT_VALUE(...)) to calculate, per housing type, the number of units added or removed, and update the number of units and useful demand per building type and construction period accordingly. These inputs also update the total roof area available for PV, and the total cooling demand as they are dependant on the total number of buildings.

2. Weather years

  • settings_weather_curve_set

If the user selects a non-default weather year, this scales preset_demand for space heating and cooling using temperature/degree-day factors derived from that weather year, and marks AREA(weather_curve_set) as non-default. This must run after stock changes so it scales correctly.

Weather years override temperature input

If the user selects a non-default weather year (settings_weather_curve_set), the flexibility_outdoor_temperature slider has no effect at all, even though the temperature with priority 0 is set after the weather years with priority 2. This happens because temperature input explicitly checks whether a weather year has been selected, and does nothing when this is the case

1. Insulation

  • households_insulation_<construction_period>
  • buildings_insulation_existing_buildings
  • buildings_insulation_new_buildings

These reduce the typical heat demand (AREA()) and preset_demand by the entered percentage, and use the resulting typical heat demand to (re)calculate insulation costs. This runs after the stock and weather updates so that insulation is applied to the correct, final number of units and to demand that has already been adjusted for the weather year.

0. Behaviour, temperature and batteries

  • households_space_heating_behaviour
  • buildings_space_heating_behaviour
  • flexibility_outdoor_temperature
  • households_flexibility_p2p_electricity_market_penetration

These are the last things to run, applying a final factor to the heat demands. Their relative execution order doesn't matter. The total number of households batteries is also calculated based on the market penetration and the total number of households.

Custom profiles for air temperature

When a user uploads a custom temperature profile in the Modify profiles section, this profile sets the outdoor temperature input in the backend and deactivates the slider in the front-end.